Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Sleep Med ; 116: 123-128, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38460417

RESUMO

BACKGROUND: Insomnia is more prevalent in females, however studies examining sex differences in response to insomnia treatment are scarce. This study assessed sex-specific differences in cognitive behavioural therapy for insomnia (CBT-I)-related changes in insomnia symptoms in a large clinical cohort. METHODS: A chart review was conducted of a clinical cohort (females n = 305, males n = 150) referred to a sleep clinic. Participants had a registered psychologist confirm diagnosis of chronic insomnia according to DSM-IV/V criteria and a Level 1 or 2 sleep study. Daily sleep diaries and questionnaires including the Insomnia Severity Index (ISI), Flinders Fatigue Scale (FFS), the Daytime Feelings and Functioning Scale (DFFS), and the Depression, Anxiety and Stress Scale-21 items (DASS), were administered at baseline, post-treatment, and three-month follow-up. Linear mixed models determined interactions between sex and timepoint on symptoms. RESULTS: Mean (SD) age was 51.7 yrs (15.7, range = 18-90 yrs), and mean BMI was 26.3 kg/m2 (4.9), neither of which differed by sex. At pre-treatment, females demonstrated higher objective total sleep time (min) [343.5 (97.6) vs 323.8 min (92.1), p = 0.044], ISI [19.7 (4.2) vs 18.6 (4.4), p = 0.033], and FFS scores [19.2 (6.0) vs 16.9 (7.2), p = 0.003]. Compared to males, females experienced a greater reduction in FFS and DFFS scores and DASS depressive symptoms (p for interaction: 0.017, 0.043, 0.016 respectively) from baseline to follow-up. The greater reduction in depressive symptoms did not persist after controlling for age, BMI, and sleep apnea severity. Subjective total sleep time similarly increased across treatment for both males [baseline: 335.7 (15.1), post: 357.9 (15.5)] and females [baseline: 318.3 (10.4), post: 354.4 (10.7)], p for interaction: 0.22. CONCLUSION: Females and males experience similar, substantial benefits from CBT-I after accounting for comorbidities, suggesting the same treatment can resolve insomnia in both sexes.


Assuntos
Terapia Cognitivo-Comportamental , Distúrbios do Início e da Manutenção do Sono , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Distúrbios do Início e da Manutenção do Sono/terapia , Caracteres Sexuais , Sono , Ansiedade/terapia , Fadiga , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38477675

RESUMO

RATIONALE: Regular, low-dose, sustained-release morphine is frequently prescribed for persistent breathlessness in chronic obstructive pulmonary disease (COPD). However, effects on daytime sleepiness, perceived sleep quality and daytime function have not been rigorously investigated. OBJECTIVES: Determine the effects of regular, low-dose, sustained-release morphine on sleep parameters in COPD. METHODS: Pre-specified secondary analyses of validated sleep questionnaire data from a randomized trial of daily, low-dose, sustained -release morphine versus placebo over four weeks commencing at 8mg or 16mg/day with blinded up-titration over two weeks to a maximum of 32mg/day. Primary outcomes for these analyses were week-1 Epworth Sleepiness Scale (ESS) and Karolinska Sleepiness Scale (KSS) responses on morphine versus placebo. Secondary outcomes included Leeds Sleep Evaluation Questionnaire (LSEQ) scores (end of weeks 1 and 4), KSS and ESS beyond week-1 and associations between breathlessness, morphine, and questionnaire scores. MEASUREMENTS AND MAIN RESULTS: 156 people were randomized. Week-1 sleepiness scores were not different on morphine versus placebo (∆ESS [95%CI] versus placebo: 8mg group: -0.59 [-1.99, 0.81], p=0.41; 16mg group: -0.72 [-2.33, 0.9], p=0.38; ∆KSS versus placebo: 8mg group: 0.11 [-0.7, 0.9], p=0.78; 16mg group: -0.41 [-1.31, 0.49], p=0.37). This neutral effect persisted at later timepoints. In addition, participants who reported reduced breathlessness with morphine at 4 weeks also had improvement in LSEQ domain scores including perceived sleep quality and daytime function. CONCLUSIONS: Regular, low-dose morphine does not worsen sleepiness when used for breathlessness in COPD. Individual improvements in breathlessness with morphine may be related to improvements in sleep.

3.
Pharmacoeconomics ; 42(5): 507-526, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38340220

RESUMO

BACKGROUND: Assessment of quality of life (QoL) in people living with sleep disorders using questionnaires is necessary to compare intervention benefits. Knowledge of the content and concepts covered by specific QoL instruments is essential to determine which instruments are best suited for conducting economic evaluations of sleep-related interventions. OBJECTIVES: This review aims to identify the QoL instruments that have been applied in economic evaluations of sleep disorder interventions and compare their conceptual overlap and content coverage using the framework of the International Classification of Functioning, Disability and Health (ICF). METHODS: A systematic review of full economic evaluations in sleep published in peer-reviewed journals from conception to 30 May, 2023 was conducted. MEDLINE, PsychInfo, ProQuest, Cochrane, Scopus, CINAHL, Web of Science and Emcare were searched for eligible studies. Studies incorporating either generic or sleep-specific QoL instruments as the primary or secondary measures of effectiveness within a full economic evaluation were included. Quality appraisal against the JBI Critical Appraisal Checklist for Economic Evaluations and EURONHEED checklists and mapping of QoL items to ICF categories were performed by two reviewers, with a third helping settle any potential differences. RESULTS: Sixteen instruments were identified as having been used in sleep health economic evaluations. The EQ-5D-3L, Epworth Sleepiness Scale, and Insomnia Severity Index were the most widely used, but the latter two are predominantly diagnostic tools and not specifically designed to guide economic evaluations. Other instruments with broader ICF content coverage have been least used, and these include the Sleep Apnea Quality of Life Index, Functional Outcomes of Sleep Questionnaire, 15 Dimensions, Short-Form 6 Dimensions, 12-item Short Form Survey, 36-item Short Form Survey and the GRID Hamilton Rating Scale for Depression. CONCLUSIONS: This study provides an overview of current QoL instruments used in economic evaluations of sleep with respect to their content coverage. A combination of generic and sleep-specific instruments with broader ICF content coverage is recommended for such evaluations.


Assuntos
Análise Custo-Benefício , Qualidade de Vida , Transtornos do Sono-Vigília , Humanos , Transtornos do Sono-Vigília/economia , Inquéritos e Questionários
4.
Sleep Med ; 113: 131-141, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38016359

RESUMO

BACKGROUND: The combination of shift work and an unmanaged sleep disorder carries health and safety risks. Yet, diagnosis rates for sleep disorders are low in shift workers. The aim of this study was to understand the experience of sleep disorder diagnosis and treatment in shift workers, and consider patient informed solutions to improve access to health services. METHODS: Semi-structured interviews were conducted with 16 Australian shift workers with a diagnosed sleep disorder. Patient journey mapping and reflexive thematic analysis were used to understand diagnosis and management experiences. RESULTS: There were highly variable experiences with diagnosis and management, often taking >5 years to seek help from a health care provider (HCP) after noticing symptoms of a sleep disorder. Three themes were constructed, including 'the cause of the problem', 'prioritising work', and '(dis)satisfaction and (dis)connection'. Extent of patient and HCP awareness of sleep disorders, and a prevailing attitude of shift work being 'the problem' impacted diagnosis, as did organisational needs (including rostering, which had both positive and negative influences on help seeking). Relationships with HCPs were important, and living on non-standard time was both a barrier and an enabler to sleep disorder care. Participants identified the need for education and awareness, prompts and easy access to screening and referral pathways, and tailored models of care. CONCLUSION: Education and awareness initiatives for shift workers, their employers and HCPs, together with development of a model of care for shift workers with sleep disorders may address some of the unique barriers to diagnosis and management.


Assuntos
Transtornos do Sono-Vigília , Humanos , Austrália , Transtornos do Sono-Vigília/diagnóstico , Transtornos do Sono-Vigília/terapia , Pesquisa sobre Serviços de Saúde
5.
J Sleep Res ; : e14051, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37833613

RESUMO

Quetiapine is an antipsychotic medication indicated for schizophrenia and bipolar disorder. However, quetiapine also has hypnotic properties and as such is increasingly being prescribed at low doses 'off-label' in people with insomnia symptoms. Pharmacologically, in addition to its dopaminergic properties, quetiapine also modulates multiple other transmitter systems involved in sleep/wake modulation and potentially breathing. However, very little is known about the impact of quetiapine on obstructive sleep apnoea (OSA), OSA endotypes including chemosensitivity, and control of breathing. Given that many people with insomnia also have undiagnosed OSA, it is important to understand the effects of quetiapine on OSA and its mechanisms. Accordingly, this concise review covers the existing knowledge on the effects of quetiapine on sleep and breathing. Further, we highlight the pharmacodynamics of quetiapine and its potential to alter key OSA endotypes to provide potential mechanistic insight. Finally, an agenda for future research priorities is proposed to fill the current key knowledge gaps.

6.
Artigo em Inglês | MEDLINE | ID: mdl-37415393

RESUMO

AIM: The 5-year survival rate of pancreatic ductal adenocarcinoma (PDAC) is approximately 11% and has only improved marginally over the last three decades. For operable PDAC, resection and adjuvant FOLFIRINOX chemotherapy is standard of care. There is growing interest in perioperative regimens to improve outcomes. The non-randomized Phase II study "Gemcitabine and Abraxane for resectable Pancreatic cancer" (GAP) demonstrated the feasibility of perioperative gemcitabine/abraxane. Long-term survival in PDAC requires an effective immune response; hence, we undertook this translational study of the GAP trial cohort to identify immune-oncology biomarkers for clinical use. METHODS: We combined Nanostring nCounter technology with immunohistochemistry to investigate the correlation between gene expression and overall patient survival. Findings were investigated in samples from the International Cancer Genome Consortium (ICGC, n = 88) and the Australian Pancreatic Genome Initiative (APGI, n = 227). RESULTS: We confirmed that human equilibrative nucleoside transporter 1 (hENT1) expression was not a prognostic marker in PDAC but patients with high levels of hENT1 were more likely to live longer than 24 months post-surgery. Additionally, CD274 (PD-L1) and two novel biomarkers of survival, cathepsin W (CTSW) and C-reactive protein (CRP), were identified in the GAP cohort (n = 19). CRP expression was confirmed in data from the ICGC. Although PD-L1 and CTSW proteins were not significant across all three cohorts, results show that low CRP mRNA and protein expression are associated with longer overall survival in all three patient groups. CONCLUSION: PDAC patients with long survival have higher hENT1 expression levels. Furthermore, CRP expression is a biomarker of poor prognosis following perioperative chemotherapy and resection in PDAC patients and thus may be useful for identifying patients who could benefit from more aggressive adjuvant strategies.

7.
NPJ Digit Med ; 6(1): 57, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36991115

RESUMO

Obstructive sleep apnea (OSA) severity can vary markedly from night-to-night. However, the impact of night-to-night variability in OSA severity on key cardiovascular outcomes such as hypertension is unknown. Thus, the primary aim of this study is to determine the effects of night-to-night variability in OSA severity on hypertension likelihood. This study uses in-home monitoring of 15,526 adults with ~180 nights per participant with an under-mattress sleep sensor device, plus ~30 repeat blood pressure measures. OSA severity is defined from the mean estimated apnea-hypopnoea index (AHI) over the ~6-month recording period for each participant. Night-to-night variability in severity is determined from the standard deviation of the estimated AHI across recording nights. Uncontrolled hypertension is defined as mean systolic blood pressure ≥140 mmHg and/or mean diastolic blood pressure ≥90 mmHg. Regression analyses are performed adjusted for age, sex, and body mass index. A total of 12,287 participants (12% female) are included in the analyses. Participants in the highest night-to-night variability quartile within each OSA severity category, have a 50-70% increase in uncontrolled hypertension likelihood versus the lowest variability quartile, independent of OSA severity. This study demonstrates that high night-to-night variability in OSA severity is a predictor of uncontrolled hypertension, independent of OSA severity. These findings have important implications for the identification of which OSA patients are most at risk of cardiovascular harm.

9.
Sleep Breath ; 27(2): 511-518, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35562555

RESUMO

PURPOSE: To evaluate the effect of long-term continuous positive airway pressure (CPAP) treatment on disease severity of obstructive sleep apnea (OSA). METHODS: We analyzed results from the Sleep Apnea and Cardiovascular Events (SAVE) study involving participants recruited at the Guangdong Provincial People's Hospital, China. Participants were aged 45-75 years with a history of cardiac or cerebrovascular disease. OSA was confirmed by home sleep apnea testing (HSAT). Participants were randomized to receive CPAP plus standard cardiovascular care (CPAP group) or standard care alone (UC group) and followed for several years. At the study conclusion, surviving participants were invited to repeat HSAT. Changes in OSA indicators were compared by independent samples t-tests and subgroup analysis was implied among groups stratified by OSA severity. RESULTS: One hundred two adults were recruited (51 per group) and followed for 48.0 ± 14.5 months. Daily CPAP usage in the CPAP group was 4.1 ± 1.9 h. AHI decreased from baseline to end-of-study in both CPAP and UC groups (- 5.0 (- 12.5,2.0), P = 0.000; - 4.0 (- 12.5,1.5), P = 0.007, respectively), with no between-group difference (P = 0.453). An improvement in nadir SpO2 showed from baseline to end-of-study in the CPAP but not UC group (2.3% ± 6.1%, P = 0.011 and - 0.7% ± 7.6%, P = 0.511, respectively; between-group difference P = 0.032). Subgroup analysis shows that CPAP could improve AHI in patients with moderate OSA (- 8.0 (- 11.8, - 2.8) in CPAP group, - 2.0 (- 0.8,6.0) in UC group, P = 0.022) and improve nadir SpO2 in patients with severe OSA (5.0 (- 0.8, - 0.8,7.0) in CPAP group, 0.0 (- 8.5,2.5) in UC group, P = 0.032). CONCLUSION: Long-term CPAP use did not result in clinically significant changes in AHI or ODI overall but showed variable effects stratified by OSA severity. CLINICAL TRIAL REGISTRATION: Registry: Clinical Trials.gov, title: Continuous Positive Airway Pressure Treatment of Obstructive Sleep Apnea to Prevent Cardiovascular Disease (SAVE), URL: www. CLINICALTRIALS: gov , identifier: NCT00738179.


Assuntos
Doenças Cardiovasculares , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Adulto , Humanos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/terapia , Comorbidade
10.
Ann Am Thorac Soc ; 20(4): 584-595, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36538809

RESUMO

Rationale: The combination of noradrenergic and antimuscarinic agents has recently been shown to improve upper-airway function and reduce obstructive sleep apnea (OSA) severity in short-term (⩽1 wk) proof-of-concept studies. Objectives: To determine the safety, tolerability, and potential efficacy of longer term use of different doses of the noradrenergic agent atomoxetine combined with the antimuscarinic oxybutynin (ato-oxy). Methods: Thirty-nine people with predominantly severe OSA received 80/5 mg ato-oxy, 40/5 mg ato-oxy, 40/2.5 mg ato-oxy, or placebo nightly for 30 days in a double-blind, randomized, parallel design. Participants completed three in-laboratory sleep studies (baseline, Night 1, and Night 30) to assess efficacy. Vital signs and objective measures of alertness and memory were assessed. In men, potential effects on prostate function were assessed using the International Prostate Symptom Score at baseline and Night 30. Potential adverse events were assessed during in-laboratory visits and via weekly phone calls. Results: Side effects were generally mild and consistent with known side-effect profiles of each individual drug (i.e., dose-dependent increases in dry mouth with oxybutynin). Heart rate increased by Night 30 in two active drug arms (mean ± standard deviation 8 ± 10 beats/min [P = 0.01] with 80/5 mg and 9 ± 14 beats/min [P = 0.02] with 40/2.5 mg vs. placebo). No clinically relevant changes in blood pressure, International Prostate Symptom Score, and measures of alertness and memory were observed between conditions. Apnea-hypopnea index (AHI) with 4% oxygen desaturation and hypoxic burden decreased by ∼50% with 80/5 mg ato-oxy from baseline but not versus placebo (e.g., AHI with 3% oxygen desaturation and AHI with 4% oxygen desaturation difference at Night 30 was -8.2 [95% confidence interval, -22.5 to 6.2] and -8.5 [95% confidence interval, -18.3 to 1.3] events/h, respectively). Conclusions: One month of nightly noradrenergic and antimuscarinic combination therapy was generally well tolerated, with a side-effect profile consistent with each agent alone, and was associated with an ∼50% reduction from baseline in a key OSA severity metric, the hypoxic burden with the highest dose combination. These findings highlight the potential to target noradrenergic and antimuscarinic mechanisms for OSA pharmacotherapy development. Clinical trial registered with www.anzctr.org.au (ACTRN 12619001153101).


Assuntos
Antagonistas Muscarínicos , Apneia Obstrutiva do Sono , Masculino , Humanos , Cloridrato de Atomoxetina/efeitos adversos , Antagonistas Muscarínicos/efeitos adversos , Apneia Obstrutiva do Sono/tratamento farmacológico , Oxigênio/uso terapêutico
11.
J Clin Sleep Med ; 19(1): 85-96, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36004739

RESUMO

STUDY OBJECTIVES: Recent findings indicate that noradrenergic and muscarinic processes are crucial for pharyngeal muscle control during sleep. However, to date, reductions in obstructive sleep apnea (OSA) severity have only been detected when noradrenergic agents are combined with an antimuscarinic. Accordingly, this study aimed to determine if reboxetine alone and combined with oxybutynin reduces OSA severity. The pathophysiological mechanisms underpinning the effects of these agents were also investigated via endotyping analysis. METHODS: Sixteen people (6 women) with OSA completed 3 polysomnograms (∼1-week washout) according to a double-blind, placebo-controlled, three-way crossover design across 2 sites. Single doses of 4 mg reboxetine, placebo, or 4 mg reboxetine + 5 mg oxybutynin were administered before sleep (order randomized). RESULTS: Reboxetine reduced the apnea-hypopnea index (primary outcome) by 5.4 (95% confidence interval -10.4 to -0.3) events/h, P = .03 (-24 ± 27% in men; -0.7 ± 32% in women). Oxybutynin did not cause additional reductions in apnea-hypopnea index. Reboxetine alone reduced the 4% oxygen desaturation index by (mean ± standard deviation) 5.2 ± 7.2 events/h and reboxetine+oxybutynin by 5.1 ± 10.6 events/h vs placebo, P = .02. Nadir oxygen saturation also increased by 7 ± 11% with reboxetine and 5 ± 9% with reboxetine+oxybutynin vs placebo, P = .01. Mechanistically, reboxetine and reboxetine+oxybutynin improved pharyngeal collapsibility and respiratory control (loop gain). Larger reductions in apnea-hypopnea index with reboxetine in men were associated with higher baseline loop gain. CONCLUSIONS: These findings show the first evidence that reboxetine alone reduces OSA severity. The data provide novel insight into the role of norepinephrine reuptake inhibitors on upper airway stability during sleep and are important to inform future pharmacotherapy development for OSA. CLINICAL TRIAL REGISTRATION: Registry: Australian New Zealand Clinical Trials Registry; Name: Reboxetine and Combination Therapy with AD128 in Sleep Apnoea Trial: A Double-Blind, 3-Way Cross-Over Study; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=374614&isReview=true; Identifier: ACTRN12620000662965. CITATION: Altree TJ, Aishah A, Loffler KA, Grunstein RR, Eckert DJ. The norepinephrine reuptake inhibitor reboxetine alone reduces obstructive sleep apnea severity: a double-blind, placebo-controlled, randomized crossover trial. J Clin Sleep Med. 2023;19(1):85-96.


Assuntos
Apneia Obstrutiva do Sono , Masculino , Humanos , Feminino , Estudos Cross-Over , Reboxetina/uso terapêutico , Austrália , Apneia Obstrutiva do Sono/terapia , Método Duplo-Cego
12.
Nat Sci Sleep ; 14: 1817-1828, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36263373

RESUMO

Purpose: Insomnia symptoms and sleep apnea frequently co-occur and are associated with worse sleep, daytime function, mental health and quality of life, compared to either insomnia or obstructive sleep apnea (OSA) alone. This study aimed to investigate the association of symptoms of co-morbid insomnia and sleep apnea (COMISA) with all-cause mortality. Patients and Methods: Wisconsin Sleep Cohort data were analysed to assess potential associations between COMISA symptoms and all-cause mortality. Nocturnal insomnia symptoms were defined as difficulties initiating sleep, maintaining sleep, and/or early morning awakenings "often" or "almost always", and/or regular sedative-hypnotic medicine use. OSA was defined as an apnea-hypopnea index ≥5/hr sleep. Participants were classified as having neither insomnia symptoms nor OSA, insomnia symptoms alone, OSA alone, or COMISA symptoms. Associations between the four groups and all-cause mortality over 20 years of follow-up were examined via multivariable adjusted Cox regression models. Results: Among 1115 adult participants (mean ± SD age 55 ± 8 years, 53% males), 19.1% had COMISA symptoms. After controlling for sociodemographic and behavioral factors, COMISA symptoms were associated with an increased risk of all-cause mortality compared to no insomnia symptoms or OSA (HR [95% CI]; 1.71 [1.00-2.93]). OSA alone (0.91 [0.53, 1.57]) and insomnia symptoms alone (1.04 [0.55, 1.97]) were not associated with increased mortality risk. Conclusion: Co-morbid insomnia symptoms and sleep apnea is associated with increased all-cause mortality risk. Future research should investigate mechanisms underpinning COMISA and the effectiveness of different treatment approaches to reduce mortality risk for this common condition.

13.
Bioinform Adv ; 2(1): vbac005, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36699384

RESUMO

Motivation: Changes in telomere length have been observed in cancer and can be indicative of mechanisms involved in carcinogenesis. Most methods used to estimate telomere length require laboratory analysis of DNA samples. Here, we present qmotif, a fast and easy tool that determines telomeric repeat sequences content as an estimate of telomere length directly from whole-genome sequencing. Results: qmotif shows similar results to quantitative PCR, the standard method for high-throughput clinical telomere length quantification. qmotif output correlates strongly with the output of other tools for determining telomere sequence content, TelSeq and TelomereHunter, but can run in a fraction of the time-usually under a minute. Availability and implementation: qmotif is implemented in Java and source code is available at https://github.com/AdamaJava/adamajava, with instructions on how to build and use the application available from https://adamajava.readthedocs.io/en/latest/. Supplementary information: Supplementary data are available at Bioinformatics Advances online.

14.
Am J Respir Crit Care Med ; 205(5): 563-569, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34904935

RESUMO

Rationale: Recent studies suggest that obstructive sleep apnea (OSA) severity can vary markedly from night to night, which may have important implications for diagnosis and management. Objectives: This study aimed to assess OSA prevalence from multinight in-home recordings and the impact of night-to-night variability in OSA severity on diagnostic classification in a large, global, nonrandomly selected community sample from a consumer database of people that purchased a novel, validated, under-mattress sleep analyzer. Methods: A total of 67,278 individuals aged between 18 and 90 years underwent in-home nightly monitoring over an average of approximately 170 nights per participant between July 2020 and March 2021. OSA was defined as a nightly mean apnea-hypopnea index (AHI) of more than 15 events/h. Outcomes were multinight global prevalence and likelihood of OSA misclassification from a single night's AHI value. Measurements and Main Results: More than 11.6 million nights of data were collected and analyzed. OSA global prevalence was 22.6% (95% confidence interval, 20.9-24.3%). The likelihood of misdiagnosis in people with OSA based on a single night ranged between approximately 20% and 50%. Misdiagnosis error rates decreased with increased monitoring nights (e.g., 1-night F1-score = 0.77 vs. 0.94 for 14 nights) and remained stable after 14 nights of monitoring. Conclusions: Multinight in-home monitoring using novel, noninvasive under-mattress sensor technology indicates a global prevalence of moderate to severe OSA of approximately 20%, and that approximately 20% of people diagnosed with a single-night study may be misclassified. These findings highlight the need to consider night-to-night variation in OSA diagnosis and management.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Polissonografia , Prevalência , Sono , Síndromes da Apneia do Sono/diagnóstico , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Adulto Jovem
15.
J Clin Sleep Med ; 17(2): 141-148, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32951632

RESUMO

STUDY OBJECTIVES: Uncertainty exists over whether continuous positive airway pressure (CPAP) treatment improves moderate to vigorous physical activity levels in those with obstructive sleep apnea. We aimed to determine effects of CPAP on moderate to vigorous physical activity among participants with co-occurring cardiovascular disease and obstructive sleep apnea. METHODS: The Sleep Apnea cardioVascular Endpoints (SAVE) trial recruited participants with confirmed cardiovascular disease history and obstructive sleep apnea, 45-75 years old. The 2,687 participants (1,346 randomized to CPAP plus usual care and 1,341 to usual care alone) were followed up for a mean of 3.7 years. Self-reported physical activity was recorded at baseline, 6, 24, and 48 months using the Godin-Shepard Leisure Time Exercise Questionnaire (LTEQ). We also determined effects on any limitation of physical activity reported on the physical functioning subscale of the 36-item short form questionnaire (SF-36) and proportions of participants reaching guideline recommended physical activity levels. RESULTS: Among 2,601 participants with available data, those in the CPAP group reported significantly more physical activity compared to the usual care group, with approximately 20% higher reported moderate activities on the LTEQ during follow-up (adjusted mean 95% confidence interval) scores: 8.7, 7.5-9.9 vs 7.3, 6.1-8.5; P = .003). Those in the CPAP group also reported less limitation in physical activity (adjusted between-group difference in SF-36 physical functioning subscale score 1.66, 95% confidence interval 0.87-2.45; P < 0.001), and more reported sufficient levels of physical activity to meet recommendations. CONCLUSIONS: CPAP has positive effects on improving physical activity levels, consistent with long-term health benefits. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Continuous Positive Airway Pressure Treatment of Obstructive Sleep Apnea to Prevent Cardiovascular Disease (SAVE); URL: https://clinicaltrials.gov/ct2/show/NCT00738179; Identifier: NCT00738179; and Registry: Australian New Zealand Clinical Trials Registry; Name: Sleep Apnea cardioVascular Endpoints study-An investigation of continuous positive airway pressure for the treatment of obstructive sleep apnea to prevent cardiovascular disease; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=83062&isReview=true; Identifier: ACTRN12608000409370.


Assuntos
Doenças Cardiovasculares , Pressão Positiva Contínua nas Vias Aéreas , Exercício Físico , Apneia Obstrutiva do Sono , Idoso , Austrália , Doenças Cardiovasculares/complicações , Humanos , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia
16.
Diabetes care ; 43(8): 1859-1867, Aug., 2020.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1128179

RESUMO

OBJECTIVE: Despite evidence of a relationship among obstructive sleep apnea (OSA), metabolic dysregulation, and diabetes, it is uncertain whether OSA treatment can improve metabolic parameters. We sought to determine effects of long-term continuous positive airway pressure (CPAP) treatment on glycemic control and diabetes risk in patients with cardiovascular disease (CVD) and OSA. RESEARCH DESIGN AND METHODS: Blood, medical history, and personal data were collected in a substudy of 888 participants in the Sleep Apnea cardioVascular Endpoints (SAVE) trial in which patients with OSA and stable CVD were randomized to receive CPAP plus usual care, or usual care alone. Serum glucose and glycated hemoglobin A1c (HbA1c) were measured at baseline, 6 months, and 2 and 4 years and incident diabetes diagnoses recorded. RESULTS: Median follow-up was 4.3 years. In those with preexisting diabetes (n = 274), there was no significant difference between the CPAP and usual care groups in serum glucose, HbA1c, or antidiabetic medications during follow-up. There were also no significant between-group differences in participants with prediabetes (n = 452) or new diagnoses of diabetes. Interaction testing suggested that women with diabetes did poorly in the usual care group, while their counterparts on CPAP therapy remained stable. CONCLUSIONS: Among patients with established CVD and OSA, we found no evidence that CPAP therapy over several years affects glycemic control in those with diabetes or prediabetes or diabetes risk over standard-of-care treatment. The potential differential effect according to sex deserves further investigation.


Assuntos
Glicemia/metabolismo , Pressão Positiva Contínua nas Vias Aéreas , Hemoglobinas Glicadas/metabolismo , Comorbidade , Apneia Obstrutiva do Sono/diagnóstico , Complicações do Diabetes , Diabetes Mellitus Tipo 2
17.
Chest ; 158(5): 2146-2154, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32679238

RESUMO

BACKGROUND: The relation of snoring to risks of stroke and other major cardiovascular (CV) events is uncertain. RESEARCH QUESTION: We aimed to determine associations of snoring patterns and major CV events in relation to OSA among participants of the international Sleep Apnea cardiovascular Endpoints (SAVE) trial. STUDY DESIGN AND METHODS: Post hoc analyses of the SAVE trial, which involved 2,687 patients with coexisting moderate-to-severe OSA and established coronary or cerebral CV disease, who were randomly allocated to CPAP treatment plus usual care or usual care alone, and followed-up for a median 3.5 years. Associations of self-reported snoring patterns (frequency and loudness) and breathing pauses collected on the Berlin questionnaire at baseline and multiple times during follow-up, and adjudicated composites of CV outcomes (primary, CV death, nonfatal myocardial infarction, nonfatal stroke, and hospitalization for unstable angina, heart failure, or transient ischemic attack; and separately of cardiac and cerebral events), were evaluated in time-dependent Cox proportional hazards models adjusted for various confounders including the apnea-hypopnea index. RESULTS: Increase (per category) of snoring frequency (adjusted hazard ratio [HR], 1.10; 95% CI, 1.02-1.20; P = .015), loudness (HR, 1.16; 95% CI, 1.06-1.27; P = .001), and breathing pauses (HR, 1.16; 95% CI, 1.08-1.25; P < .001) at any time point during follow-up were each associated with the primary composite CV outcome. These associations were driven by significant associations for cerebral rather than cardiac events, and positive interactions between the three snoring patterns for cerebral events. There was no significant interaction between CPAP treatment and snoring variables for cerebral events. INTERPRETATION: Snoring in patients with OSA with established CV disease is associated with greater risks of cerebral but not cardiac events, independent of CPAP treatment and frequency of apnea and hypopnea events. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT00738179; URL: www.clinicaltrials.gov.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Medição de Risco/métodos , Autorrelato , Apneia Obstrutiva do Sono/terapia , Ronco/complicações , Acidente Vascular Cerebral/etiologia , Idoso , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Austrália do Sul/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Inquéritos e Questionários , Taxa de Sobrevida/tendências
18.
Chest ; 158(6): 2621-2631, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32679239

RESUMO

BACKGROUND: Traditional methods for the quantification of OSA severity may not encapsulate potential relationships between hypoxemia in OSA and cardiovascular risk. RESEARCH QUESTION: Do novel nocturnal oxygen saturation (Spo2) metrics have prognostic value in patients with OSA and high cardiovascular event risk? STUDY DESIGN AND METHODS: We conducted post hoc analyses of the Sleep Apnea Cardiovascular Endpoints (SAVE) trial. In 2687 individuals, Cox proportional hazards models that were stratified for treatment allocation were used to determine the associations between clinical characteristics, pulse oximetry-derived metrics that were designed to quantify sustained and episodic features of hypoxemia, and cardiovascular outcomes. Metrics included oxygen desaturation index, time <90% Spo2, average Spo2 for the entire recording (mean Spo2), average Spo2 during desaturation events (desaturation Spo2), average baseline Spo2 interpolated across episodic desaturation events (baseline Spo2), episodic desaturation event duration and desaturation/resaturation-time ratio, and mean and SD of pulse rate. RESULTS: Neither apnea-hypopnea index, oxygen desaturation index, nor any of the novel Spo2 metrics were associated with the primary SAVE composite cardiovascular outcome. Mean and baseline Spo2 were associated with heart failure (hazard ratio [HR], 0.81; 95% CI, 0.69-0.95; P = .009; and HR, 0.78; 95% CI, 0.67-0.90; P = .001, respectively) and myocardial infarction (HR, 0.86; 95% CI, 0.77-0.95; P = .003; and HR, 0.81; 95% CI, 0.73-0.90; P < .001, respectively). Desaturation duration and desaturation/resaturation time ratio, with established risk factors, predicted future heart failure (area under the curve, 0.86; 95% CI, 0.79-0.93). INTERPRETATION: Apnea-hypopnea index and oxygen desaturation index were not associated with cardiovascular outcomes. In contrast, the pattern of oxygen desaturation was associated with heart failure and myocardial infarction. However, concomitant risk factors remained the predominant determinants for secondary cardiovascular events and thus deserve the most intensive management.


Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Hipóxia , Infarto do Miocárdio , Oximetria , Polissonografia , Medição de Risco , Apneia Obstrutiva do Sono , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Correlação de Dados , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Frequência Cardíaca , Humanos , Hipóxia/complicações , Hipóxia/diagnóstico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Avaliação de Resultados em Cuidados de Saúde , Oximetria/métodos , Oximetria/estatística & dados numéricos , Polissonografia/métodos , Polissonografia/estatística & dados numéricos , Valor Preditivo dos Testes , Prognóstico , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia
19.
Diabetes Care ; 43(8): 1859-1867, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32291275

RESUMO

OBJECTIVE: Despite evidence of a relationship among obstructive sleep apnea (OSA), metabolic dysregulation, and diabetes, it is uncertain whether OSA treatment can improve metabolic parameters. We sought to determine effects of long-term continuous positive airway pressure (CPAP) treatment on glycemic control and diabetes risk in patients with cardiovascular disease (CVD) and OSA. RESEARCH DESIGN AND METHODS: Blood, medical history, and personal data were collected in a substudy of 888 participants in the Sleep Apnea cardioVascular Endpoints (SAVE) trial in which patients with OSA and stable CVD were randomized to receive CPAP plus usual care, or usual care alone. Serum glucose and glycated hemoglobin A1c (HbA1c) were measured at baseline, 6 months, and 2 and 4 years and incident diabetes diagnoses recorded. RESULTS: Median follow-up was 4.3 years. In those with preexisting diabetes (n = 274), there was no significant difference between the CPAP and usual care groups in serum glucose, HbA1c, or antidiabetic medications during follow-up. There were also no significant between-group differences in participants with prediabetes (n = 452) or new diagnoses of diabetes. Interaction testing suggested that women with diabetes did poorly in the usual care group, while their counterparts on CPAP therapy remained stable. CONCLUSIONS: Among patients with established CVD and OSA, we found no evidence that CPAP therapy over several years affects glycemic control in those with diabetes or prediabetes or diabetes risk over standard-of-care treatment. The potential differential effect according to sex deserves further investigation.


Assuntos
Glicemia/metabolismo , Doenças Cardiovasculares/terapia , Pressão Positiva Contínua nas Vias Aéreas , Diabetes Mellitus Tipo 2/etiologia , Apneia Obstrutiva do Sono/terapia , Idoso , Glicemia/análise , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/epidemiologia , Comorbidade , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/terapia , Feminino , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/metabolismo , Controle Glicêmico , Humanos , Masculino , Pessoa de Meia-Idade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/epidemiologia , Estado Pré-Diabético/etiologia , Estado Pré-Diabético/terapia , Fatores de Risco , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Padrão de Cuidado , Cooperação e Adesão ao Tratamento/estatística & dados numéricos
20.
Int J Stroke ; 15(8): 858-865, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32013799

RESUMO

BACKGROUND AND AIM: Controversy exists regarding cardiovascular risk in relation to sleep duration. We determined sleep duration and major recurrent cardiovascular event associations in patients with obstructive sleep apnoea and established cardiovascular disease. METHODS: Secondary analyses of the international, multicenter, Sleep Apnea Cardiovascular Endpoints trial. Sleep duration was estimated from overnight home oximetry (ApneaLink monitor) used for obstructive sleep apnoea diagnosis. Cox proportional hazards models were used to determine associations of categorized sleep duration (<6 h, 6-8 h (reference), and >8 h) and major cardiovascular outcomes: primary composite of cardiovascular death, non-fatal myocardial infarction, non-fatal stroke, and any hospitalization for unstable angina, heart failure, or transient ischemic attack; secondary composite of cardiac and cerebral (stroke/transient ischemic attack) events. RESULTS: Oximetry-derived sleep duration estimates were available in 2687 participants (mean 61.2 years, 80.9% males) who experienced a total of 436 cardiovascular events over a mean follow-up of 3.7 years. Compared to the reference category, sleep duration was not associated with risk of the primary composite cardiovascular outcome (adjusted hazard ratio (HR) 1.00, 95% confidence interval 0.76-1.33, and HR 1.22, 95% confidence interval 0.98-1.52, for sleep duration <6 and >8 h, respectively). However, long sleep was associated with increased cerebral events (HR 1.67, 95% confidence interval 1.17-2.39; P = 0.005) and stroke alone (HR 1.79, 95% confidence interval 1.22-2.63; P = 0.003). CONCLUSIONS: Long sleep duration is associated with an increased risk of stroke but not cardiac events in obstructive sleep apnoea patients with existing cardiovascular disease. CLINICAL TRIAL REGISTRATION: The trial is registered at ClinicalTrials.gov (NCT00738179).


Assuntos
Doenças Cardiovasculares , Infarto do Miocárdio , Apneia Obstrutiva do Sono , Acidente Vascular Cerebral , Doenças Cardiovasculares/epidemiologia , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais , Fatores de Risco , Sono , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Acidente Vascular Cerebral/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...